Increasing Protection - Arc Fault Detection Devices

Arc fault protection devices (AFDD) use microprocessors to identify characteristic current flow and voltage curves that indicate an arc fault and automatically trip the affected circuit.

This significantly reduces the risk of fire due to faulty conductors and connections. The protective function of the AFDD has already proven its worth internationally, and has been used in Germany since February 2016.

The 18th edition of BS 7671, when published in July, recommends the use of these to provide additional protection against fire.

Monitoring via Microprocessor

An AFDD is activated by both series and parallel arc faults. Unlike circuit breakers or RCDs, an AFDD does not have an electromechanical trigger, but utilises electronic technology to analyse the signature (waveform) of an arc. It reliably differentiates between an arc fault and the signature (waveform) in normal switching and control events, preventing false tripping.

Potential Causes

Arc faults can be caused by all types of line faults and worn contacts;
  • Kink / break in a cable
  • Cable wear due to frequent use
  • Cable damage resulting from drilling or construction work
  • Incorrect wire stripping
  • Incorrect bending radii
  • Loose screwed connections
  • Defective wall plugs
  • Rodents biting cables

An AFDD will trip the circuit when a potentially hazardous arc occurs, eliminating the resulting fire hazard.

Ring Final Circuits

Contrary to common belief, AFDD’s do offer protection against arc faults in ring final circuits and to the equipment being fed from this circuit. A series arc fault in one leg however, is unlikely to be at a dangerous level so will not be detected. This is due to current in this instance flowing around the other leg of the ring. A series arc fault will be detected in equipment and in flexible cables connected to the ring final circuit. Parallel arc faults are detected and disconnected in all parts of the ring circuit and on all connected equipment.

Effective Areas Of Protective Devices Depending On Fault Position & Type

Fault BetweenShort CircuitOverloadResidual CurrentSerial ArcParallel Arc
 
 
 
 
 
 
L-L
MCB / RCBO
MCB / RCBO
-
-
-
L-N
MCB / RCBO
MCB / RCBO
-
AFDD
AFDD
L-PE
MCB / RCBO
MCB / RCBO
RCD / RCBO
-
RCD / RCBO / AFDD

Products Coming Soon

Product List

Cat Ref
Description
ARC906U
AFDD/MCB 1P+N 6kA B-6A 2M
ARC910U
AFDD/MCB 1P+N 6kA B-10A 2M
ARC916U
AFDD/MCB 1P+N 6kA B-16A 2M
ARC920U
AFDD/MCB 1P+N 6kA B-20A 2M
ARC925U
AFDD/MCB 1P+N 6kA B-25A 2M
ARC932U
AFDD/MCB 1P+N 6kA B-32A 2M
ARC940U
AFDD/MCB 1P+N 6kA B-40A 2M
ARC956U
AFDD/MCB 1P+N 6kA C-6A 2M
ARC960U
AFDD/MCB 1P+N 6kA C-10A 2M
ARC966U
AFDD/MCB 1P+N 6kA C-16A 2M
ARC970U
AFDD/MCB 1P+N 6kA C-20A 2M
ARC975U
AFDD/MCB 1P+N 6kA C-25A 2M
ARC982U
AFDD/MCB 1P+N 6kA C-32A 2M
ARC990U
AFDD/MCB 1P+N 6kA C-40A 2M
 
 
ARC506U
AFDD/MCB 1P+N 10kA B-6A 2M
ARC510U
AFDD/MCB 1P+N 10kA B-10A 2M
ARC516U
AFDD/MCB 1P+N 10kA B-16A 2M
ARC520U
AFDD/MCB 1P+N 10kA B-20A 2M
ARC525U
AFDD/MCB 1P+N 10kA B-25A 2M
ARC532U
AFDD/MCB 1P+N 10kA B-32A 2M
ARC556U
AFDD/MCB 1P+N 10kA C-6A 2M
ARC560U
AFDD/MCB 1P+N 10kA C-10A 2M
ARC566U
AFDD/MCB 1P+N 10kA C-16A 2M
ARC570U
AFDD/MCB 1P+N 10kA C-20A 2M
ARC575U
AFDD/MCB 1P+N 10kA C-25A 2M
ARC582U
AFDD/MCB 1P+N 10kA C-32A 2M

Further Information

The Hager technical team contribute to a number of key industry publications, for AFDD we have been involved in the preparation of the BEAMA Guide to Arc Fault Detection Devices (AFDDs)
Author: Paul Collins
Posted: 10th April 2018
Get in contact: technical@hager.co.uk | Twitter